TIMP2 ELISA Kit (Horse)

Katalog-Nummer OKCD01484

Size : 96Wells

Marke : Aviva Systems Biology

Contact local distributor :


Telefonnummer : +1 850 650 7790

Datasheets/ManualsPrintable datasheet for TIMP2 ELISA Kit (Horse) (OKCD01484)
Product Info
Predicted Species ReactivityEquus caballus|Horse
ApplicationELISA-Sandwich
ELISA Kit Detection MethodColorimetric
ELISA Kit Duration3h
ELISA Kit Linearity
Sample1:2 Dilution1:4 Dilution1:8 Dilution1:16 Dilution
Serum (n=5)81-90%88-95%98-105%88-98%
EDTA Plasma (n=5)86-101%84-92%89-102%87-104%
Heparin Plasma (n=5)97-104%87-101%80-95%79-102%
ELISA Kit PrincipleThe test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Tissue Inhibitors Of Metalloproteinase 2 (TIMP2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Tissue Inhibitors Of Metalloproteinase 2 (TIMP2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Tissue Inhibitors Of Metalloproteinase 2 (TIMP2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Tissue Inhibitors Of Metalloproteinase 2 (TIMP2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
ELISA Kit Range7.8-500ng/mL
ELISA Kit Recovery
MatrixRecovery Range (%)Average (%)
Serum (n=5)83-9389
EDTA Plasma (n=5)94-10398
Heparin Plasma (n=5)84-10495
ELISA Kit ReproducibilityIntra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tissue Inhibitors Of Metalloproteinase 2 (TIMP2) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tissue Inhibitors Of Metalloproteinase 2 (TIMP2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
ELISA Kit Component
ComponentAmount
Anti-TIMP2 Microplate96 Wells (12 x 8 Well Strips)
TIMP2 Lyophilized Standard2 x 500 ng
100X Biotinylated TIMP2 Detector Antibody120 uL
Avidin/HRP Conjugate120 uL
Standard Diluent1 x 20 mL
Detector Antibody Diluent1 x 12 mL
Conjugate Diluent1 x 12 mL
30X Wash Buffer1 x 20 mL
TMB Substrate1 x 9 mL
Stop Solution1 x 6 mL
Reconstitution and Storage2°C to 8°C|-20°C
Sample TypeSerum, plasma, tissue homogenates and other biological fluids
Sensitivity< 2.9 ng/mL
SpecificityThis assay has high sensitivity and excellent specificity for detection of Tissue Inhibitors Of Metalloproteinase 2 (TIMP2). No significant cross-reactivity or interference between Tissue Inhibitors Of Metalloproteinase 2 (TIMP2) and analogues was observed.
Assay InfoAssay Methodology: Quantitative Sandwich Immunoassay
Gene SymbolTIMP2
Alias SymbolsTissue inhibitor of metalloproteinases 2.
NCBI Gene Id100034134
Protein NameMetalloproteinase inhibitor 2
Description of TargetComplexes with metalloproteinases (such as collagenases) and irreversibly inactivates them.
Uniprot IDO77717
Protein Accession #XP_014593727.1
Nucleotide Accession #XM_014738241.1
Protein Size (# AA)91