Home » Products » Horse PLAU(Urokinase-Type Plasminogen Activator) ELISA Kit
This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti PLAU/uPA antibody. Add standard and properly diluted sample into relevant well respectively. After incubation, wash unbound components. Add biotinylated detection antibody. Then, it binds with PLAU/uPA bound to precoated antibody. Wash unbound components and add HRP-Streptavidin Conjugate (SABC). Wash unbound components again and add TMB substrate solution. Then, TMB was catalyzed by HRP to produce a blue color product that turned yellow after adding a stop solution. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of PLAU/uPA in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
- Catalogue No.:
- EHS0022
- Alias:
- Urokinase-type plasminogen activator ELISA Kit, U-plasminogen activator ELISA Kit, uPA ELISA Kit, Urokinase-type plasminogen activator long chain A ELISA Kit, Urokinase-type plasminogen activator short chain A ELISA Kit, Urokinase-type plasminogen activator chain B ELISA Kit, PLAU ELISA Kit
- Species:
- Horse
- Range:
- 62.5-4000pg/ml
- Sensitivity:
- 37.5pg/ml
- SPECIFICATIONS
- FIGURES
- CONDITIONS
- Product Name
- Horse PLAU(Urokinase-Type Plasminogen Activator) ELISA Kit
- Alias
- Urokinase-type plasminogen activator ELISA Kit, U-plasminogen activator ELISA Kit, uPA ELISA Kit, Urokinase-type plasminogen activator long chain A ELISA Kit, Urokinase-type plasminogen activator short chain A ELISA Kit, Urokinase-type plasminogen activator chain B ELISA Kit, PLAU ELISA Kit
- Catalogue No.
- EHS0022
- Size
- 48T/96T
- Species
- Horse
- UniProt ID
- F7BT48
- Sample Type
- Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
- Detection Method
- Sandwich ELISA, Double Antibody
- Detection Wavelength
- OD450
- Reaction Duration
- 4 hours
- Range
- 62.5-4000pg/ml
- Sensitivity
- 37.5pg/ml
- Storage
- 2-8°C(Sealed), Don't cryopreserve.
- Specificity
- Specifically binds with PLAU/uPA , no obvious cross reaction with other analogues.
- ELISA Kit Components
Kit Components Item Size(48T) Size(96T) Storage Condition for Opened Kit E001 ELISA Microplate(Dismountable) 8×6 8×12 Put the rest strips into a sealed foil bag with the desiccant. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C E002 Lyophilized Standard 1vial 2vial Put the rest standards into a desiccant bag. Stored for 1 month at 2-8°C; Stored for 6 month at -20°C E003 Biotin-labeled Antibody(Concentrated, 100X) 60ul 120ul 2-8°C (Avoid Direct Light) E034 HRP-Streptavidin Conjugate(SABC, 100X) 60ul 120ul E024 TMB Substrate 5ml 10ml E039 Sample Dilution Buffer 10ml 20ml 2-8°C E040 Antibody Dilution Buffer 5ml 10ml E049 SABC Dilution Buffer 5ml 10ml E026 Stop Solution 5ml 10ml E038 Wash Buffer(Concentrated, 25X) 15ml 30ml E006 Plate Sealer 3 pieces 5 pieces E007 Product Description 1 copy 1 copy - Required Instruments and Reagents
-
- Microplate reader (wavelength: 450nm)
- 37°C incubator (CO2 incubator for cell culture is not recommenced.)
- Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
- Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
- Sterile tubes and Eppendorf tubes with disposable tips
- Absorbent paper and loading slot
- Deionized or distilled water
- Assay Procedure Summary
-
- Step 1: Add 100ul standard or sample into each well, seal the plate and statically incubate for 90 minutes at 37°C.
- Washing: Wash the plate twice without immersing.
- Step 2: Add 100ul biotin-antibody working solution, seal the plate and statically incubate for 60 minutes at 37°C.
- Washing: Wash the plate three times and immerse for 1min each time.
- Step 3: Add 100ul HRP-Streptavidin Conjugate (SABC) working solution, seal the plate and statically incubate for 30 minutes at 37°C.
- Washing: Wash the plate five times and immerse for 1min each time.
- Step 4: Add 90ul TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37°C. (Accurate TMB visualization control is required.)
- Step 5: Add 50ul stop solution. Read at 450nm immediately and calculate.
- Standard Curve
-
This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.)
Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.
STD.(pg/ml) OD-1 OD-2 Average 0 0.1 0.102 0.101 62.5 0.168 0.172 0.17 125 0.216 0.222 0.219 250 0.31 0.318 0.314 500 0.469 0.483 0.476 1000 0.859 0.883 0.871 2000 1.554 1.6 1.577 4000 2.351 2.419 2.385 - Recovery
-
Add a certain amount of PLAU/uPA into the sample. Calculate the recovery by comparing the measured value with the expected amount of PLAU/uPA in the sample.
Sample Type Recovery Range(%) Average(%) serum(n=10) 88-104 94 EDTA plasma(n=10) 92-104 92 Heparin plasma(n=10) 85-98 96 - Linearity
-
Dilute the sample with a certain amount of PLAU/uPA at 1:2, 1:4 and 1:8 to get the recovery range.
Sample Type 1:2 1:4 1:8 serum(n=10) 84-99% 83-92% 81-100% EDTA plasma(n=10) 82-98% 84-100% 82-100% Heparin plasma(n=10) 81-93% 82-95% 86-95% - Precision(%)
-
Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.
Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.
Item Intra-assay Precision Inter-assay Precision Sample 1 2 3 1 2 3 n 20 20 20 20 20 20 Mean (pg/ml) 126.7 492.1 2016 125.5 507.3 2028 Standard deviation 6.77 23.87 104.43 5.97 25.82 97.14 CV(%) 5.34 4.85 5.18 4.76 5.09 4.79 - Stability
-
Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.
ELISA kit(n=5) 37°C for 1 month 2-8°C for 6 months Average(%) 80 95-100